Who Set Your Testosterone Range, and With What Machine?
The range printed beside a woman's testosterone describes one lab's method and one group of women, and many printouts never say which.
The case file
- Evaluation of reference ranges of four circulating sex steroids from dried blood spots in women aged 18-40 years.J Steroid Biochem Mol Biol · 2025In 120 healthy premenopausal women aged 18 to 40 the median testosterone was 0.75 nmol/L by LC-MS/MS. All sex steroids were significantly lower on hormonal contraception.
- Liquid chromatography-tandem mass spectrometry assay for androstenedione, dehydroepiandrosterone, and testosterone with pediatric and adult reference intervals.Clin Chem · 2010Median testosterone was 270 ng/L in premenopausal and 180 ng/L in postmenopausal women, with no fall by age after menopause.
- The Simultaneous measurement of serum testosterone and 5α-dihydrotestosterone by gas chromatography-mass spectrometry (GC-MS).Clin Chim Acta · 2018Immunoassays agreed well with mass spectrometry in men but read higher at low concentrations in women.
- Challenges in developing accurate assays for the measurement of estradiol and testosterone in postmenopausal women.Menopause · 2025Mass spectrometry shows higher accuracy for steroid hormones. The US CDC is building a standardisation programme and intervals for postmenopausal women.
Score your printout: five checks, five minutes, tonight
Your lab printout and a pen (5 min) · 5 min
- Read the line under the testosterone result. If it names a method (LC-MS/MS, mass spectrometry, immunoassay, CLIA or ECLIA), score 1 and write the name down.
- Write down the units: nmol/L, ng/dL or ng/L. Score 1 if they sit next to the result.
- Check for a separate range line for women and the group it names (before or after menopause, an age band). Score 1 if it exists.
- Look for a note on cycle, pregnancy or contraception. Score 1 if there is one.
- Circle who set the range, the lab or a published paper. Score 1 if it says.
- After the five checks, add your points. Then convert your result to nmol/L: ng/L divided by 288, or ng/dL divided by 28.8. Set it beside 0.75 nmol/L, the middle of 120 healthy women aged 18 to 40 measured by mass spectrometry [[40473059]]. It is a reference point, nothing more.
What you end up withpoints out of five, plus your result in nmol/L
- Four or five pointsclearThe page gives enough detail to compare your number with published groups. That does not prove the range fits you.Check that the group on the page fits your age and whether you take hormonal contraception.
- Two or three pointsmoderatePart of the story is missing, most often the method or the group.Ask the lab: which method, which group of women. Write down the answer and the date.
- Zero or one pointmarkedNothing on the page says how the range was made, so you cannot tell what normal means here.Request the full report from the lab with the method and the source of the range.
When this test liesThe 0.75 figure is wrong for you on a hormonal contraceptive, because values run lower [[40473059]]. It does not apply in pregnancy, where ranges change by week [[38870268]]. It is not hers after menopause [[20489135]]. It also fails when the method is buried in the small print of a PDF, so scroll to the last page before scoring zero.
The line is drawn from a group of women someone else picked
A reference range is a summary. A lab takes a group of women judged healthy, measures them, and prints where most of them fall. Change the group or the instrument and the range changes.
One 2025 study measured 120 healthy women aged 18 to 40, none pregnant or breastfeeding. Using a method that weighs the molecules themselves, the middle value for the group was 0.75 nmol/L 2. A middle value is the midpoint: half the women above, half below. Treat it as one reference point. It came from 120 women in one place, with blood dried on paper cards 2.
Five-year age bands inside that group made no real difference 2. A range for a woman of 30 can list no age and still be right.
A 2010 paper gave other middle values, in other units: 270 ng/L before menopause and 180 ng/L after 4. Divide ng/L by 288 to get nmol/L. That makes about 0.94 and 0.63 (my arithmetic, not the paper's). Different women, different year, different units, and the numbers do not match. After menopause, testosterone in that paper did not fall with age 4. A missing age band there can be right too.
Your number depends on the instrument as much as on your blood
Two methods are in use. Immunoassay uses antibodies, proteins that latch onto the hormone. It is cheap and fast, and most labs run it. Mass spectrometry weighs the molecules directly. A 2025 review says mass spectrometry is more accurate for steroid hormones, while immunoassays can give clinically meaningful results, especially at high concentrations 5.
Women's testosterone sits at the low end, where immunoassay is weakest. A 2018 comparison found the two methods agreed well in men. In women, at low concentrations, the antibody method read higher 1.
So a number from the antibody test, placed against a range built with the other method, can look higher than it is. Mass spectrometry does not win everywhere: at high concentrations the antibody test holds up 5. Find the method on your page first. The same blood can give a different number on a different instrument.
The pill, pregnancy and menopause each move the limits
Women taking a systemic hormonal contraceptive had significantly lower levels of all the sex steroids measured, testosterone included 2. A range built only on women who were not taking one may not describe you.
Pregnancy changes it more. In 600 healthy pregnant women, testosterone rose from early to late pregnancy, which is why pregnancy needs ranges by week and an ordinary range does not apply 3.
After menopause the 2010 paper gives its own middle values 4. If your page has one line for all women, ask whose.
Whether the day of the cycle matters is disputed: the 2025 study found minimal variation 2, the 2018 paper says ranges should be split by cycle phase 1. I would not plan your blood draw around either.
The US national health agency, the CDC, is building a standard for measuring steroid hormones by mass spectrometry, and testosterone intervals for women after menopause 5. Neither is finished.
Until then each lab picks its own method and its own group of women. A lab that prints its own interval is following the only rules it has.
If it does not go to plan
- The patient portal shows only a number and a flag, no method.Ask the lab or the clinic for the full laboratory report. The method is usually in the footer or on the last page.
- Your units are ng/dL and every number in this article is nmol/L.Divide ng/dL by 28.8, or ng/L by 288, to get nmol/L. Write both numbers on the printout.
- The range lists no age at all.Age bands made no real difference in women of 18 to 40 [[40473059]], so a missing one can be right. Ask which group the range was built on instead.
- You are on a hormonal contraceptive and the range does not mention it.Tell the clinician at the start of the appointment. Do not change or pause the pill because of this article.
Honestly: what is settled and what is not
Established: methods differ, and the antibody test reads higher in women at low levels. Not established here: how much higher, any range for immunoassay, how labs choose their healthy women or which cut they use, ethnic variation, and what to do when a result falls below a range. The 0.75 figure comes from one small group.
What to do with this
- Find the method under your result: mass spectrometry or immunoassay, the antibody test 5
- Write down the units and convert to nmol/L before comparing: ng/L divided by 288
- Ask which group of women your range belongs to, because the pill, pregnancy and menopause each change it 234
- Read your page against 0.75 nmol/L, the middle of 120 women, as a landmark only 2
- Say at the appointment: "Which method measured my testosterone, and which group is this range for?"
Questions people also ask
Is mass spectrometry always more accurate than immunoassay?
Why does my testosterone range have no age band?
Does the contraceptive pill change my testosterone result?
In the 2025 study of 120 women, every sex steroid measured, testosterone included, was significantly lower in women taking a systemic hormonal contraceptive 2. Tell the clinician you take one. Keep taking it as prescribed unless a clinician decides otherwise.
Sources
Every number above comes from one of these. Each carries its PMID, the number it is filed under in the US National Library of Medicine, if you want to look it up yourself.
- The Simultaneous measurement of serum testosterone and 5α-dihydrotestosterone by gas chromatography-mass spectrometry (GC-MS).
- Evaluation of reference ranges of four circulating sex steroids from dried blood spots in women aged 18-40 years.
- Gestational Age-specific Reference Intervals for Androgens in Pregnancy.
- Liquid chromatography-tandem mass spectrometry assay for androstenedione, dehydroepiandrosterone, and testosterone with pediatric and adult reference intervals.
- Challenges in developing accurate assays for the measurement of estradiol and testosterone in postmenopausal women.
This article is information, not medical advice, diagnosis or treatment. Reference ranges, doses and protocols differ between people and between laboratories. Talk to a qualified clinician before changing anything about your care.