📖Max Hormone Labs
THE RECEIPTS · NOVEMBER 2026

On the Pill, 45 of 100 Healthy Women Fail the 1.8 Cortisol Line

The 1.8 µg/dL line clears 95 of 100 healthy adults but only 55 of 100 women on combined pills, and the printout does not say which group you are in [[3]].

The case file

  1. Overnight Dexamethasone Suppression Test: Enhanced Accuracy With Late-afternoon Cortisol and Morning/Late-afternoon ACTH.Prospective single-centre cohort, J Clin Endocrinol Metab, 175 people · 2026At 1.8 µg/dL the morning test cleared 95% of healthy adults, 55% of combined-pill users and 17% of people with kidney disease.
  2. Method-Specific Cortisol and Dexamethasone Thresholds Increase Clinical Specificity of the Dexamethasone Suppression Test for Cushing Syndrome.Retrospective analytical study, Clin Chem, 400 samples · 2021A method-specific line of 2.4 raised the share of non-Cushing's samples cleared from 67.5% to 92.4%; dexamethasone level did not vary with pill use.
  3. Serum cortisol assay performance following the 1 mg overnight dexamethasone suppression test.Comparative analytical study, Ann Clin Biochem, 77 samples · 2023Abbott Alinity read 18.8 nmol/L lower than the reference method on average, 20.7 in females against 17.2 in males.
  4. The addition of corticotropin-releasing hormone to 2-day low dose dexamethasone suppression test provides additional case detection.Retrospective cohort, Endocrine, 65 Cushing disease and 42 comparison · 20235 of 65 people with Cushing disease had cortisol of 1.4 µg/dL or lower and were found only after adding CRH.
  5. Lowering the dexamethasone suppression test cut-off: is it time yet?Literature review, J Endocrinol Invest · 2025Some studies propose a lower line near 1.2 µg/dL to capture at-risk people, at the cost of more false alarms.

Four lines from your printout, ten minutes tonight

Your lab printout, a pen and a sheet of paper (10 min) · 10 min

  1. Write the cortisol value after dexamethasone and its unit. If it is in nmol/L, divide by 27.6 and write the µg/dL (unit arithmetic).
  2. Write the hour the blood was drawn.
  3. Write the lab's printed line and the name of its method. If neither is printed, write "not printed".
  4. Look at your pill pack and write yes or no: a pill with oestrogen in that period. Change nothing about it.
  5. Mark where your value falls: below 1.2, 1.2 to 1.8, 1.8 to 2.4, or above 2.4.
  6. Count your factors that can move the result, 0 to 3: a pill with oestrogen; method not printed, or the lab's line is not 1.8; no dexamethasone blood level printed beside the cortisol. Write the count next to the rung.

What you end up withCortisol in µg/dL on the four-rung ladder, plus a count of factors from 0 to 3

  • Below 1.2clearUnder every line quoted in these papers [[40856981]]. With 0 factors the line raises no question. With 1 to 3 factors it still sits below all of them.Nothing to ask about the line. If you still feel unwell, ask what else was tested.
  • 1.2 to 1.8mildGrey zone. Below the usual line, yet some people with signs of cortisol excess sit here [[40856981]], and 5 of 65 with Cushing disease were found only with CRH [[36917416]].Ask whether your other findings, such as blood pressure, sugar and bones, call for more.
  • 1.8 to 2.4moderateAbove the usual line. With 1 to 3 factors, the line itself may be part of the reason [[40972562]][[33997885]]. With 0 factors, less so.Ask about the method and a repeat, or ACTH [[40972562]] or a dexamethasone level.
  • Above 2.4markedAbove the lines in these papers, so the line is no longer the main question, whatever the factor count.Ask what the next test is and when. Your doctor decides what it means.

When this test liesThe printout does not show whether dexamethasone was taken as scheduled, and low dexamethasone levels went with false alarms in one study [[33997885]]. With kidney disease only 17 of 100 healthy people clear the line [[40972562]]. The Abbott analyser can read low, more so in women [[37208338]].

What the flag above 1.8 means on your printout

Late at night you take dexamethasone, a steroid that tells the body to switch off its own cortisol. Next morning blood is drawn. In Cushing's syndrome, long-term cortisol excess, the switch-off fails and cortisol stays high. If yours stays above the line, the printout flags it.

The line is 1.8 µg/dL 1. Lowering it flags more healthy people 2.

The 1.8 is a property of the test. The same blood value reads differently depending on the hour, the pill pack and the machine that measured it. The printout has one column for the result and one for the flag, and none for any of that.

On a pill with oestrogen, about 45 of 100 healthy women land above the line

A 2026 study ran the overnight test on 175 people, among them 60 healthy adults, 29 women on combined pills and 29 people with kidney disease 1. At 1.8, 95 of 100 healthy adults came out below the line. For the pill group the number was 55 of 100. For kidney disease it was 17 of 100 1.

For a healthy woman on a combined pill, the flag is close to a coin toss.

The obvious suspect is the tablet itself, absorbed differently. A study of 400 samples measured dexamethasone in the blood and found that its level did not vary with pill use, sex or age 3. The same study found that low dexamethasone levels went with false alarms, which fits a missed or poorly taken tablet 3.

How oestrogen shifts the cortisol result has not been tested. Explanations are circulating, but they are guesses, and I will not hand you one as fact.

The hour of the draw, the machine and a second hormone move the same number

When blood was taken at 4 pm instead of the morning, the line cleared 100 of 100 healthy adults and 79 of 100 women on pills 1.

A second measurement did more. ACTH, the hormone from the pituitary gland that tells the adrenals to make cortisol, was checked with a line of 10 pg/mL. It cleared every healthy adult and every pill user 1.

The machine matters too. In one lab study, a line of 2.4 chosen for a single method cleared about nine in ten people without Cushing's instead of two in three, and still caught every Cushing's case in the 400 samples 3.

One analyser, Abbott Alinity, read lower than the reference method by 18.8 nmol/L on average, and lower again in women, by 20.7 against 17.2 in men 4. In µg/dL that is roughly 0.7 (my arithmetic). A reading that low pushes toward missing a case, the opposite of the pill problem. The authors conclude that each method needs its own line 4.

The line also misses people, and nobody agrees where to move it

A 2025 review looked at people whose adrenal glands showed a lump found by chance on a scan. Many had the metabolic, heart, bone and muscle changes typical of cortisol excess even with results below 1.8 2. Some studies propose a line near 1.2. The price is more false alarms 2.

A group of 65 people with Cushing disease, the pituitary form, shows the grey zone in numbers. In 5 of them, 7.7%, cortisol was 1.4 or lower on the two-day low-dose test. Only adding CRH, a hormone that stimulates the pituitary, reclassified them correctly 5. That 1.4 belongs to the combined test, not to the overnight one.

Measuring dexamethasone in the blood alongside cortisol pushed the share of people without Cushing's who came out clear to 97 of 100 5.

What to say with this printout in your hand

Say: "I was on a combined pill with oestrogen when this was drawn. Does your 1.8 line account for that?"

Ask which method the lab used and why its printed line is what it is. If the line is not printed, ask for it.

Ask whether ACTH, or the dexamethasone level in the blood, can be added or repeated. In the one study that tested pill users, ACTH cleared every one of them, which cortisol alone did not 1.

Bring your four lines on one sheet. Your pill and your dexamethasone stay as prescribed until the doctor who prescribed them says otherwise.

A flag on a printout says the number crossed a line. It does not say whom the line was drawn for.

If it does not go to plan

  • My printout gives only nmol/LDivide by 27.6 to get µg/dL. It is unit arithmetic, so check the result against the lab's own flag.
  • The draw hour is not on the printoutAsk the lab or your doctor's office for the collection time. Write "not known" until then; a morning draw and a 4 pm draw read differently [[40972562]].
  • I take a pill without oestrogen, or I am not sure what mine containsRead the active ingredients on the pack and write them down. The papers cover combined pills only, so tell the doctor exactly what you take.
  • I have two results from different labsDo not compare them directly. Write each method and printed line beside its number, since methods differ [[37208338]].

Honestly: what is settled and what is not

The 55-of-100 result comes from 29 women in one centre, so it shows a direction, not an exact rate [[40972562]]. There are no data on pills without oestrogen, body weight, cycle phase, or age within women. The 2.4 line and the Abbott bias come from analytical studies without patient outcomes, and the bias may not be constant across the cortisol range [[33997885]][[37208338]]. Nobody has shown what happens to women who followed any of these steps.

What to do with this

  • Check who the flag was drawn for: the 1.8 µg/dL line clears 95 of 100 healthy adults but 55 of 100 healthy women on combined pills 1
  • Write four lines from the printout: value, hour, printed line and method, and pill with oestrogen yes or no
  • Do not blame absorption of the tablet first: dexamethasone in the blood did not vary with pill use 3
  • Ask whether ACTH 1 or a dexamethasone level can be added to sharpen the picture
  • Ask about a lower or method-specific line if you sit below 1.8: lines of 1.2, 1.4 and 2.4 come from single papers 253

Questions people also ask

Does cortisol above 1.8 after dexamethasone mean Cushing's?

No. Above the line means the result needs a closer look. Among healthy women on combined pills, about 45 of 100 land above 1.8 1. Only your doctor can diagnose, using more than this one number.

Can my pill raise the result?

In one study women on combined pills came out below the line far less often than healthy adults, 55 of 100 against 95 of 100 1. Dexamethasone levels did not differ with pill use 3. Do not stop the pill without your doctor.

Is 1.8 the same line in every lab?

No. One study found a line of 2.4 fitted its own method better 3. Another found the Abbott analyser reads lower than the reference method, more so in women 4. Look for the method and the line printed on your own report.

Sources

Every number above comes from one of these. Each carries its PMID, the number it is filed under in the US National Library of Medicine, if you want to look it up yourself.

  1. Overnight Dexamethasone Suppression Test: Enhanced Accuracy With Late-afternoon Cortisol and Morning/Late-afternoon ACTH.J Clin Endocrinol Metab, 2026 · PMID 40972562
  2. Lowering the dexamethasone suppression test cut-off: is it time yet?J Endocrinol Invest, 2025 · PMID 40856981
  3. Method-Specific Cortisol and Dexamethasone Thresholds Increase Clinical Specificity of the Dexamethasone Suppression Test for Cushing Syndrome.Clin Chem, 2021 · PMID 33997885
  4. Serum cortisol assay performance following the 1 mg overnight dexamethasone suppression test.Ann Clin Biochem, 2023 · PMID 37208338
  5. The addition of corticotropin-releasing hormone to 2-day low dose dexamethasone suppression test provides additional case detection.Endocrine, 2023 · PMID 36917416

This article is information, not medical advice, diagnosis or treatment. Reference ranges, doses and protocols differ between people and between laboratories. Talk to a qualified clinician before changing anything about your care.

Max Zimin

I am not a clinician, and that is the point: I had no stake in defending the ranges. I read the primary literature and the laboratory guidance, I find out who chose a number and in what year, and I write it down with the document attached. I also write the books sold on this site. Everything in a column can be checked against its source, because that is the only kind of argument worth making here.